Sunday, October 4, 2015

Emerson Liebert GXT4 UPS Web Card

I was asked to setup an Emerson Liebert GXT4 UPS IntelliSlot (IS) Web Card for SNMP and monitor its performance in Solarwinds NPM. The IS web card slot is located on top of the UPS fan and has two onboard ports: an Ethernet port for LAN/IP connectivity and an RS232/serial port for local console administration. We use Liebert for the initial username and password.



EMERSON NETWORK POWER IS WEB CARD

Initializing...

Initializing network...
Interface callback: FNS_IF_EVENT_INTERFACE_UP for eth0
Network initialization completed successfully!
Initial DNS resolution complete!

Interface callback: FNS_IF_EVENT_ADDRESS_READY for fe80::202:99ff:fe16:5123.

Booting...

****************************************************************
IntelliSlot Web Card Boot Loader

(C)Copyright 2000-2014 Emerson Network Power

Build Label .............: IS-WEBCARD_HID9_5.300.2_082246

Software Version Number .: v5.300.2
Source Control Number ...: 00082246
Product ID ..............: 00000002
Hardware ID .............: 00000009
Header Revision Number ..: 00000001
Firmware Checksum .......:   0x075C
****************************************************************


****************************************************************
IntelliSlot Web Card

(C)Copyright 2000-2014 Emerson Network Power

Build Label .............: IS-WEBCARD_HID9_5.300.2_082246

Software Version Number .: v5.300.2
Source Control Number ...: 00082246
Product ID ..............: 00000002
Hardware ID .............: 00000009
Header Revision Number ..: 00000001
Firmware Checksum .......:   0x5F13
****************************************************************

Calculating Boot Checksum
Boot Checksum:          0x075C
Saved Boot Checksum:    0x075C
Checksum Valid

Calculating Application Checksum
Application Checksum:          0x5F13
Saved Application Checksum:    0x5F13
Checksum Valid

MAC Address:          00-02-99-16-51-23
Serial Number:        417771G109C2015MAR200123
Manufacture Date:     MAR 20 2015

Initializing...

Initializing network...
Interface callback: FNS_IF_EVENT_INTERFACE_UP for eth0
Network initialization completed successfully!
Initial DNS resolution complete!

Interface callback: FNS_IF_EVENT_ADDRESS_READY for fe80::202:99ff:fe16:5123.
SNMP Research SNMP Agent Resident Module Version 15.3.1.15
Copyright 1989, 1990, 1991, 1992, 1993, 1994, 1995, 1996, 1997, 1998, 1999, 2000, 2001, 2002 SNMP

Research, Inc.

Web Server Ready!

SNTP task started!

Interface callback: FNS_IF_EVENT_ADDRESS_READY for 202.78.x.x
DhcpCallback: DHCP_LEASE_IS_BOUND, IP 202.78.x.x
Received DHCPv4 DNS Address: 8.8.8.8
IPv4 DHCP Address returned

IP Address: 202.78.x.x
Netmask: 255.255.255.224
Gateway: 202.78.y.y
Broadcast Address: 0.0.0.0
DHCP/BootP Server: 202.78.y.y

IPv4 DNS Server: "8.8.8.8"

Emerson Network Power IntelliSlot Web Card

GXT4-3000RT230

System Information Menu
------------------------
1: Name           Uninitialized
2: Contact        Uninitialized
3: Location       Uninitialized
4: Description    Uninitialized


<ESC>: Cancel menu level

Please select a key ?> 1

Enter name (Max 255 chars) ?> ups-test


Emerson Network Power IntelliSlot Web Card

GXT4-3000RT230
GO TO MAIN MENU AND DO 'EXIT AND SAVE' TO SAVE YOUR CHANGES!

System Information Menu
------------------------
1: Name           ups-test
2: Contact        Uninitialized
3: Location       Uninitialized
4: Description    Uninitialized


<ESC>: Cancel menu level

Please select a key ?> 3

Enter location (Max 64 chars) ?> Warehouse


Emerson Network Power IntelliSlot Web Card

GXT4-3000RT230
GO TO MAIN MENU AND DO 'EXIT AND SAVE' TO SAVE YOUR CHANGES!

System Information Menu
------------------------
1: Name           ups-test
2: Contact        Uninitialized
3: Location       Warehouse
4: Description    Uninitialized


<ESC>: Cancel menu level


Emerson Network Power IntelliSlot Web Card

GXT4-3000RT230

IP Network Settings Menu
-------------------------
1: Boot/IP Settings
2: Domain Name Server (DNS) Settings
3: Management Protocol
4: Web Server
5: Telnet Server
6: Time (SNTP)
7: Change Administrator User Name/Password
8: Change General User Name/Password
9: Reset WEB Authentication to Factory Defaults

<ESC>: Cancel menu level

Please select a key ?> 7

Enter Administrator User Name, press enter for [Liebert]: (Max 32 chars) ?> admin

Enter New Password: (Max 32 chars) ?> ******

Verify Password: ?> ******
New Settings will take effect when saved


Emerson Network Power IntelliSlot Web Card

GXT4-3000RT230
GO TO MAIN MENU AND DO 'EXIT AND SAVE' TO SAVE YOUR CHANGES!

Emerson Network Power IntelliSlot Web Card

GXT4-3000RT230

IP Network Settings Menu
-------------------------
1: Boot/IP Settings
2: Domain Name Server (DNS) Settings
3: Management Protocol
4: Web Server
5: Telnet Server
6: Time (SNTP)
7: Change Administrator User Name/Password
8: Change General User Name/Password
9: Reset WEB Authentication to Factory Defaults

<ESC>: Cancel menu level

Please select a key ?> 1


GXT4-3000RT230

Boot/IP Settings Menu
----------------------
1: Speed/Duplex       Auto
2: IPv4 Settings
3: IPv6 Settings
4: Ping Settings


<ESC>: Cancel menu level

Please select a key ?> 2

Emerson Network Power IntelliSlot Web Card

GXT4-3000RT230

IPv4 Settings Menu
-------------------
1: IPv4 Mode          DHCP
   IP Address         202.78.x.x
   Netmask            255.255.255.224
   Gateway            202.78.y.y


<ESC>: Cancel menu level

Please select a key ?> 1
 Valid Selections:
 ------------------
 1.  Static
 2.  BootP
 3.  DHCP
 4.  Unconfigured
Select IPv4 Mode: ( <Esc> - Cancel) ?> 1

<ESC>: Cancel menu level


Emerson Network Power IntelliSlot Web Card

GXT4-3000RT230
GO TO MAIN MENU AND DO 'EXIT AND SAVE' TO SAVE YOUR CHANGES!

IPv4 Settings Menu
-------------------
1: IPv4 Mode          Static
2: IP Address         0.0.0.0
3: Netmask            0.0.0.0
4: Gateway            0.0.0.0


<ESC>: Cancel menu level

Please select a key ?> 2
Enter IP address [xxx.xxx.xxx.xxx] ?> 202.78.x.x



Emerson Network Power IntelliSlot Web Card

GXT4-3000RT230
GO TO MAIN MENU AND DO 'EXIT AND SAVE' TO SAVE YOUR CHANGES!

IPv4 Settings Menu
-------------------
1: IPv4 Mode          Static
2: IP Address         202.78.x.x
3: Netmask            0.0.0.0
4: Gateway            0.0.0.0


<ESC>: Cancel menu level

Please select a key ?> 3
Enter Netmask address [xxx.xxx.xxx.xxx] ?> 255.255.255.224



Emerson Network Power IntelliSlot Web Card

GXT4-3000RT230
GO TO MAIN MENU AND DO 'EXIT AND SAVE' TO SAVE YOUR CHANGES!

IPv4 Settings Menu
-------------------
1: IPv4 Mode          Static
2: IP Address         202.78.30.21
3: Netmask            255.255.255.224
4: Gateway            0.0.0.0


<ESC>: Cancel menu level

Please select a key ?> 4
Enter Default Gateway[xxx.xxx.xxx.xxx] ?> 202.78.x.x



Emerson Network Power IntelliSlot Web Card

GXT4-3000RT230

Main Menu
----------
1: System Information
2: IP Network Settings
3: Messaging
4: Factory Settings
5: Firmware Updates

q: Quit and abort changes
x: Exit and save


Please select a key ?> x
Exiting and saving...


Configuration saved successfully






No comments:

Post a Comment